Floating License Alarm

The alarm is applicable only to the Flex License and Floating License and to the following products: Mediant 500, Mediant 500L, Mediant 800, Mediant 1000, Mediant 2600, Mediant 4000, Mediant 9000, and Mediant Software.

acFloatingLicenseAlarm

Alarm

acFloatingLicenseAlarm

OID

1.3.6.1.4.1.5003.9.10.1.21.2.0.138

Description

The alarm is sent when insufficient memory resources (physical memory) exist for the capacity of the user-defined (Custom) Allocation Profile configured for the Floating License on the Floating License page.

Default Severity

Warning

Source Varbind Text

Board#1

Event Type

processingErrorAlarm

Additional Info

Detailed explanation of the problematic parameter, requested and actual value. For example: "SignalingSessions – requested 10000, allocated 1000"

Probable Cause

communicationsProtocolError

Severity

Condition

Text

Corrective Action

Warning

An attempt was made to configure a customized Allocation Profile with values that exceed the device's capacity support based on physical memory.

"Not enough memory to allocate for 'custom' profile."

Configure an Allocation Profile within the bounds of the device's capacity support.